Quality Controls for medical imaging systems enable us to check the operating condition of imaging devices over time, to guarantee optimum performance and reliable patient and worker radiation protection.

BIOMEDIQA is positioned as a service provider for internal quality controls of your medical imaging devices, governed by the ANSM.

The BIOMEDIQA team has all the expertise and skills needed to work on Interventional Radiology, Conventional Radiology and Scanography equipment.

Don't lose control

BIOMEDIQA ‘s missions are based on methods inspired by project management. In this way, you retain full control over your quality controls, with complete transparency.

The little extras that make us different

  • Interventions possible from 7:00 am to 10:00 pm
  • Specialists in the field of medical imaging
  • A speaker dedicated to your facility
  • Interventions possible within 5 working days thanks to our national presence
  • Checks carried out on calibrated and periodically verified equipment
  • Digital delivery of your service reports via a secure cloud platform.

Our offers

1

Commissioning IQC

  • On-site intervention prior to first use of the unit
  • An intervention report sent after the intervention
  • Provision of control images
2

Monthly IQC

  • One on-site intervention per month +/- 5 days.
  • An intervention report sent for each intervention carried out
3

Half-yearly IQC

  • One on-site intervention every six months +/-15 days.
  • An intervention report sent for each intervention carried out
4

Annual IQC

  • On-site intervention every year on an anniversary date +/- 1 month.
  • An intervention report sent for each intervention carried out
  • Provision of inspection images for each operation
5

CQI maintenance suite

  • On-site intervention as soon as possible after maintenance
  • An intervention report sent for each intervention carried out
  • Provision of inspection images for each intervention

1. Mechanical characteristics of gas pedals

2. Beam characteristics in the photon regime, in static mode

3. Electron beam characteristics

6. Monitor (gas pedals)

  • Coherence of primary and secondary chains
  • Reproducibility of monitor units
  • Proportionality of monitor units to dose
  • Stability of each beam’s calibration over time

7. Processing table

  • Vertical displacement
  • Isocentric table rotation
  • Tabletop rigidity and horizontality
  • Treatment table position scale

9. Portal imaging system

  • Anti-collision systems
  • Display of source-to-sensor distance
  • Mechanical backlash as a function of vertical support movement
  • Mechanical play as a function of treatment arm rotation
  • Matching the image to the radiation field
  • Contrast and spatial resolution
  • Noise
  • Image consistency
  • On-screen distance measurement tool
  • Spatial distortion